Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Coluna/Columna ; 11(3): 240-241, July-Sept. 2012. ilus
Article in Portuguese | LILACS | ID: lil-654890

ABSTRACT

Descreve-se um suporte de cabeça para cirurgia da coluna vertebral, que permite a colocação da cabeça do paciente em alinhamento neutro com o corpo e monitorização da posição de olhos, boca, nariz e tubo orotraqueal, evitando danos decorrentes de mau posicionamento durante a cirurgia.


We describe a head support for spinal surgery that allows the placement of the patient's head in neutral alignment with the body and monitoring the position of the eyes, mouth, nose and orotracheal tube, preventing damages from poor positioning during surgery.


Se describe un soporte de cabeza para la cirugía de columna vertebral que permite la colocación de la cabeza del paciente en alineación neutra con el cuerpo y el control de la posición de ojos, boca, nariz y tubo oro-traqueal, evitando los daños causados por el posicionamiento incorrecto durante la cirugía.


Subject(s)
Surgical Equipment , Spine , Prone Position , Patient Positioning
2.
Coluna/Columna ; 10(1): 58-61, 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-591214

ABSTRACT

OBJETIVO: O objetivo deste trabalho é estudar, em peças anatômicas; a relação entre os parafusos bicorticais pela técnica de Harms e Melcher e a artéria carótida interna. MÉTODOS: Nossa amostra consiste em cinco cadáveres. RESULTADOS: Os resultados encontrados foram: a média da menor distância entre o orifício de saída do parafuso e a borda medial da artéria carótida interna direita foi de 11,55 mm (com variação de 10,05 a 14,23 mm), enquanto do lado esquerdo a média foi de 7,50 mm (variando de 2,75 a 12,42 mm). A média da menor distância entre a borda posterior da artéria carótida interna e a cortical anterior da massa lateral de C1 à direita foi de 4,24 mm (variando de 2,08 a 7,48 mm), enquanto do lado esquerdo a média obtida foi de 2,98 mm (com variação de 1,83 a 3,83 mm). CONCLUSÃO: Os resultados encontrados estão de acordo com os estudos similares existentes na literatura que enfatizam a necessidade de uma avaliação imaginológica criteriosa da posição anatômica da artéria carótida interna antes da utilização de parafusos bicorticais na massa lateral de C1 por via posterior.


OBJECTIVE: The objective of this study is to study the relationship between bicortical screws and the internal carotid artery, in anatomical body parts, in screw fixation by the Harms and Melcher technique. METHODS: Our sample consisted of five cadavers. RESULTS: The results were as follows: the average shortest distance between the outlet of the screw and the medial edge of the right internal carotid artery was 11.55 mm (range 10.05 to 14.23 mm), while on the left side, the average was 7.50 mm (ranging from 2.75 to 12.42 mm). The average shortest distance between the posterior edge of the internal carotid artery and the anterior cortical C1 lateral mass on the right was 4.24 mm (ranging from 2.08 to 7.48 mm), while the left side, the average was 2.98 mm (ranging from 1.83 to 3.83 mm). CONCLUSION: The results are consistent with similar studies in the literature that emphasize the need for a careful assessment of images of anatomical position of the internal carotid artery prior to the use of bicortical screws in the C1 lateral mass by posterior access.


OBJETIVO: O objetivo de este estudio es, en las piezas anatómicas, la relación entre los tornillos bicorticales, mediante la técnica de Harms y Melcher, y la arteria carótida interna. MÉTODOS: La muestra se compone de cinco cadáveres. RESULTADOS: Los resultados fueron: la distancia más corta promedio, entre la salida del tornillo y el borde medial de la arteria carótida interna derecha, fue 11,55 mm (rango de 10,05 a 14,23 mm), mientras que, en la izquierda, el promedio fue 7,50 mm (rango 2,75 a 12,42 mm). La distancia más corta promedio, entre el borde posterior de la arteria carótida interna y la cortical anterior C1 de la derecha, fue 4,24 mm (que van desde 2,08 hasta 7,48 mm), mientras que, en el lado izquierdo, el promedio fue 2,98 mm. (que van desde 1,83 hasta 3,83 mm). Conclusión: Los resultados son consistentes con estudios similares en la literatura que hacen hincapié en la necesidad de una evaluación cuidadosa de las imágenes y posición anatómica de la arteria carótida interna, antes del uso de tornillos bicorticales de masa lateral de C1 por acceso posterior.


Subject(s)
Humans , Atlas , Bone Screws , Cadaver , Carotid Artery, Internal , Spine , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL